Installation guide

STEP
5:
INSTALL
THE
MOUNTING
PLATE
TO
THE
WALL
THE
OVEN
MUST
BE
CONNECTED
TO
AT
LEAST
ONE
WALL
STUD.
1.
Draw
a
vertical
line
on
the
wall
at
the
center
of
the
30"
wide
space.
Use
the
mounting
plate
as
the
template
for
the
rear
wall.
Place
the
mounting
plate
on
the
wall,
making
sure
that
the
tabs
are
against
the
bottom
of
the
cabinet.
Line
up
the
notch
and
center
line
on
the
mounting
plate
to
the
center
line
on
the
wall.
.
While
holding
the
mounting
plate
with
one
hand,
draw
circles
on
the
wall
at
holes
"A",
"B",
"C"
and
"D".
Four
holes
must
be
used
for
mounting.
If
the
holes
are
not
used,
the
installation
will
not
be
secure.
Installer
must
use
these
holes
for
proper
installation.
Use
toggle
bolts
through
these
holes
unless
one
of
them
lines
up
with
a
stud.
Use
a
lag
screw
for
studs.
See
Figure
26.
NOTE:
Draw
a
fifth
circle
inside
area
"E",
through
one
of
the
holes
to
match
the
location
of
a
stud.
For
wall
vented:
The
oven
requires
a
rear
wall
cutout
opening
for
the
rear
wall
duct
and
the
exhaust
adaptor
must
be
attached
to
the
mounting
plate.
See
the
next
page
on
how
to
prepare
the
rear
wall
cutout
opening
and
the
exhaust
adaptor/mounting
plate
for
wall
vented.
3.
Drill
holes
through
the
circles.
If
there
is
a
stud,
drill a
3/16"
hole
for
lag
screws.
Two
or
preferably
four
lag
screws
at
holes
"A"
and
"C",
or
"B"
and
“D"
must
be
used
to
secure
mounting
plate
to
wall.
If
there
is
no
stud,
drill a
3/4"
hole
for
toggle
bolts.
Make
sure
to
use
at
least
1
lag
screw
at
holes
of
area
"E"
in
a
stud,
and
4
toggle
bolts
at
holes
"A",
"B",
"C"
and
"D"
in
the
drywall
or
the
plaster.
.
Attach
the
plate
to
the
wall.
To
use
spring
toggle
head
bolts:
Remove
the
toggle
wings
from
the
bolts.
Insert
the bolts
into
the
mounting
plate
and
replace
the
spring
toggle
heads
to
3/4"
past
the
bolt
ends.
Insert
the
spring
toggle
heads
into
the
holes
in
the
wall
to
mount
the
bracket.
You
may
pull
forward
on
the
bracket
to
help
in
tightening
the
toggle
bolts.
Tighten
all
bolts.
See
Figure
27.
3/16
Hole
on
Studs
5/8
Hole
on
Drywall
Only
Minimum
66"
From
the
Floor
For
Wall-
Vented
Only
/——_
i
/
#
Mounting
» +
Plate
f
i
+
Draw
Lines
1
5
onStuds
4
4
\
~——
Draw)
4
Center
Line,
ps
S
‘Li
'
|
9
s
{
4g
Support
Tab
(1-piece
Mounting
Plate)
Minimum
66"
From
the
Floor
|
Support
Tab
3/16
Hole
on
Studs
5/8
Hole
on
Drywall
Only
For
Wall-
Vented
Only
/—<_
=
2,
‘Bal
————
+
1
‘=
t
rt
+
i
Draw
Lines
1 3
on
Studs
1
~—
Draw’
aw
yy
Center
Line
|B]
\f
T
1
1
1
Mounting
|
Plate
\
[D]
ooo
—z—__
Support
Tab
oO
Ger
GO
Oe
ofS
O.
\
Support
Tab
(3-piece
Mounting
Plate)
Mounting
Plate
:
>
F
voagle
Bolt
|):
Fe
a
lt
}
iW
Wall
°
Figure
26
Space
More
Than
Wall
Thickness
Toggle
Wings
Figure
27
15
HSITSNa