f READ AND SAVE THESE INSTRUCTIONS SF..AIRIS OWner'S Model No. 758.144115 QUIETCOMFORT WHOLE HOUSE HUMIDHFIER FOR YOUR READ ALL mNSTRUCTIONS CAREFULLY Sears, Roebuck Part No. SP6520 11 Gallon Output Digita_ Readout with • Operating _nstructions • Parts List and Co., Hoffman Estates, IL 60179 U.S.A.
FULL ONE YEAR WARRANTY ON HUMmDmFIER _f within one (1) year from the date of purchase, this humidifier falls due to a defect in material or workmanship, Sears will repair it, free of charge. If within two (2} years from the date of purchase, the motor fails due to defect in materia_ or workmanship, Sears witl repair it free of charge. This warranty service is available by simply returning the humidifier to the nearest Sears Service Center/Department throughout the United States.
Know Your Humidifier Fan Assembly Bottle Handles Speed Base Casters 42 -14411 Description 11 Ga!lon Output/24 hrs Capacity of Bottle Capacity of Base Sq. Ft. Coverage Fan Speeds Replacement Filter Power Light Fill Light Auto Humidistat Auto 1,9 Gal!ons 2.0 Gallons 2300 4 42:14906 Yes Yes Yes Shut Off Controls Yes Electronic (Push Button) Casters CUL Listed Yes (4) Yes Volts 120 A,C. Hertz 60 0,80 Amps Watts * Based on an area with average and an 8 foot ceiling height.
Humidifier Operation __ Your new Sears humidifier is designed satisfy home humidity requirements through the principle water in the air. of evaporation After water to the humidifier, is added to of Humidified air is then reteased through the top the filter begins to soak up the water and will become saturated in approximately 30 Dry air enters minutes.
Location Instructions iWARNING: not For your use humidifier _damaged safety, do if any parts or mss Step 1 Place humidifier own -- are The humidifier should be positioned with Step 2 the back (cord exit side) and left side, at l ng. least 2 inches away from the wall Air needs to enter through all of the louvers on a flat level surface an area of house where in in the housing is humidifier most humidity assembly to operate in order for the at peak efficiency.
Water Fill WARNING: To reduce shock, always before cleaning WARNING: the risk unplug of humidifier or shock hazard, water into control the risk of fire do not pour or spH[ or motor area. If controls get wet, comp[etemy authorized and have unit checked by service personnel before plugging Z/ / or servicing. To reduce let them ,'_ l _ Bottle dry / in. .- This humidifier is designed for use with the water bottle located to the right of the upper grill.
4. Listen for air bubbles. around valve the ' E-Z-Fill Look for leaks Side-Cap" retighten the "E-Z-Fill repeat steps 1-4. off excess Position water the water or see leaks, Side-Cap" The water bottle as necessary plunger. 5. If you hear air bubbles Wipe and and may be filled during operation. from To benefit from less frequent filling let the humidifier exhaust both the water from the bottle and base before filling. The unit is now ready bottle at anytime for operation.
Operating Speed Button This humidifier Humidifier is equipped speed fan contro!, speed button the settings UM and Each Controls (cont'd) with a 4= push of the advances the mode through of WHSPER, NIGH, LOW. The selected MEDIo setting is dis= played on the digital readout. The higher the setting, the faster water is evaporated and released into the air.
Operating Refill Light The humidifier Humidifier Controls (cont'd) base and bottle hold approxi_ mately 2 gallons of water each. The bottle empties into the base during operation. When the base empties the amber REFILL light will illuminate informing additional water is required. Also at this time the unit will automatically switch into "DRY OUT MODE" and continue to run on WNmSPER speed until the filter is dry.
Humidifier Operations Check Fi_ter Indicator The ability of any humidifier to efficiently supply humidity output reIies heavily on the condition of the filter.As the filter loads with trapped impurities found in water it gradually loses its wicking capability. When tNs happens moisture output is red_._cedand the humidifier has to work longer to satisfy the selected setting. When such a condition occurs, a flashing "CHECK FILTER" message wilt be displayed.
Using Your Humidifier 1. Place the humidifier where to run it and be sure and full of water. 2. Press the POWER the humidifier will illuminate. you intend it is plugged operate light IMPORTANT: condensation on WHISPER speed percentage play. will read 65 on the digRal dis- initial Humidifier start and the SET fan should section 3. Wait a few seconds takes a ROOM During or wails. lowered forms.
Replacement shock or injury from and Care of Filters moving parts, always unplug humidifierthe risk beforeof WARNBNG: To reduce removing or replacing any parts. CAUTION: growth To help retard keep maximum and bacteria efficieno cy, the fimter should be replaced at [east once per season, or more often under hard water conditions. Use Sears filter. recommended replacement To replace the filter in your Kenmore Quiet Comfort Whole House humidifier, follow the instructions Unplug humidifier.
Replacement 5, Install and Care of Filters a new filter (42_14906) into the (continued) Base Uprights base. Coil the filter and position it between the uprights in the bottom of the base, The start and finish of the coil should be captured the base should be resting the base, 6, at the centre (see diagram) _se on the floor of Return the housing assembly of the base.
Cleaning WARNING: injury, Your Humidifier To reduce fire the risk or damage of Step 2 To Remove to humidifier, use only cleaners specifically recommended for humidifiers. Never use fmammabme, combustible or poio sonous materials to clean your humidifier. To reduce the risk of scalds and never put damage to humidifier, hot water in humidifier. Grasp cleaning base should a. easier, be empty 3. Take note of the filter position.
Cleaning Step End Maintenance 1. Scale Fill the humidifier solution white vinegar. Let stay 20 minutes. Clean all interior brush. Dampen surfaces a soft cloth with 3. Rinse thoroughly with clean water to remove solution. Disinfecting 1. warm and cleaning surfaces normally Empty 3. Let humidifier dry completely before storing. Do not store with water inside base or bottle. 4. Store 5.
Troubleshooting Trouble Probable Cause Remedy Red power tight and digital display not illuminated. • No Power. • Power button has not been depressed, • Check 120 volt power source. • Press power button once to turn on. Fan not operating (Red power light and digital display is illuminated), • ROOM humidity tevet is 1% or more above SET humidity level. • Raise SET humidity tevel if desired. Fan running continuously. • SET humidity level is 65%.
Troubleshooting Trouble Probable Cause Remedy Dispiay blinks or fan moves stightty when humidifier is plugged in. • Normal • No action required. "CHECK FILTER" message does not appear even when illter is dirty or humidifier performance is clearly reduced. • Humidistat on power cord is being heated, • Move power cord away from any source of heat or obstruction. Fan operating stower than speed registered on digital display. • Humidifier MODE".
Repair Parts Parts 17 List for Sears Humidifier Mode_ No. 758.144115 Iy 16 \ 18
Repair Parts Parts AN_ays Key No List for Sears Humidifier Mode_ No. 758.144115 order Part by part number No.
For the repair or replacement parts you need Call 7 am - 7 pro, 7 days a week 1 -S00-366-PART {1-800-366-7278) For in-home major brand repair service Call 24 hours a day, 7 days a week 1 -S00-4-REPAIR (1-800-473-7247) For the location of a Sears Repair Sewice Center in your area Call 24 hours a day, 7 days a week 1-800-488-1 222 Fer infermatien en purchasing a Sears Maintenance Agreement erte inquire abeut an existing Agreement Call 9 am - 5 pro, Monday-Saturday 1-800-827-6655 Atr_er_cas Nep_ir S