Installation guide

Installation Instructions
Electrical Connections cont.
OR
I THREE-CONDUCTOR BRANCH I
CIRCUIT CONNECTION
When connecting to a 3-conductor
branch circuit, if local codes permit:
a.Connect the bare oven ground conductor
with the crimped neutral (white) lead to the
branch circuit neutral (white or gray in
color), using wire nut.
Ground and
Neutral Wires
b.Connect the oven red lead to the branch
circuit red lead, using wire nut.
c.Connect the oven black lead to the branch
circuit black lead in accordance with local
codes, using wire nut.
d.lnstall Junction Box Cover.
Do not shorten the flexible conduit.The
conduit strain Relief Clamp must be
securely attached to the junction box
and the flexible conduit must be
securely attached to the clamp. If the
flexible conduit will not fit within the
clamp, do not install the oven until a
clamp of the proper size is obtained.
NOTE TO ELECTRICIAN: The 3 power
leads supplied with this appliance are UL
recognized for connection to larger gauge
household wiring. The insulation of these 3
leads is rated at temperatures much higher
than the temperature rating of household
wiring. The current carrying capacity of the
conductor is governed by the temperature
rating of the insulation around the wire,
rather than the wire gauge alone.
_ WARNING: Improper
connection of aluminum
house wiring to copper leads
can result in an electrical hazard or
fire, Use only connectors designed
for joining copper to aluminum and
follow the manufacturer's
recommended procedure closely.
9