User's Manual
PrOblem"
Dehumidifier does not
start.
Possible Causes
Dehumidifier is not
operating as
intended.
The dehumidifier is un-
plugged.
The fuse is blown / cir-
cuit breaker is tripped.
Dehumidifier has
reached the user set
humidity level or the
bucket is full
Bucket is not in the
)roper position.
Power Failure.
Not enough time al-
lowed for unit to remove
moisture.
Solutions
Make sure the dehumidifier's plug is pushed
completelyinto the outlet.
Check the house fuse / circuitbreaker box and
replace fuse or reset breaker.
The dehumidifier automaticaI]y turns off when
either condition occurs. Change to a lower
setting or empty the water bucket and replace
)roperly.
The bucket must be in place and securely
seated for the dehumidifier to operate.
There is a protective time delay (up to 3 rain.)
to prevent tdpping of the compressor overload.
For this reason, the unit may not start normal
dehumidification for 3 rain. after it ispowered
back on.
When first instal[ed, allow at least 24 hours to
achieve the desired humidity level.
Filter Indicator is lit. Filter needs to be Once filter has been cleaned, press the FIL-
cleaned every 250 hours TER button for 3 seconds to turnthe filter
of use. indicator off.
11
Airflow is restricted. Make sure there are no curtains, blinds, or
furniture b]ocking the side or back of the de-
humidifier.
Dirty filter. See the Cleaning The Air Filter section
The user set Humidity To reduce moisture, press the down arrow
Level may not be set low button to lower the percent humiditydesired in
enough, the room, or set the dehumidifierto CO for
continuousoperation.
Doors and windows may Check that all doors, windows, and other
not be closed tightly, openings are securely closed.
Water is not draining Make sure the drain is placed below the drain
through drain hose connectornozzle to al[ow gravityto drain the
water (Refer to Gravity Drain Hose section in
this manual).
Room temperature is too Moistureremoval is best at higher room tern-
low. _eratures. Lower room temperatures will re-
duce the moisture removal rate. This model is
designed to operate at temperatures above
41 °F.