Use and Care Manual
Table Of Contents
- Slide Number 1
- Slide Number 2
- Slide Number 3
- Slide Number 4
- Slide Number 5
- Slide Number 6
- Slide Number 7
- Slide Number 8
- Slide Number 9
- Slide Number 10
- Slide Number 11
- Slide Number 12
- Slide Number 13
- Slide Number 14
- Slide Number 15
- Slide Number 16
- Slide Number 17
- Slide Number 18
- Slide Number 19
- Slide Number 20
- Slide Number 21
- Slide Number 22
- Slide Number 23
- Slide Number 24
- Slide Number 25
- Slide Number 26
- Slide Number 27
- Slide Number 28
- Slide Number 29
- Slide Number 30
- Slide Number 31
- Slide Number 32
- Slide Number 33
- Slide Number 34
- Slide Number 35
- Slide Number 36
- Slide Number 37
- Slide Number 38
- Slide Number 39
- Slide Number 40
- Slide Number 41
- Slide Number 42
- Slide Number 43
- Slide Number 44
- Slide Number 45
- Slide Number 46
- Slide Number 47
- Slide Number 48
- Slide Number 49
- Slide Number 50
- Slide Number 51
- Slide Number 52
- Slide Number 53
- Slide Number 54
- Slide Number 55
- Slide Number 56
- Slide Number 57
- Slide Number 58
- Slide Number 59
- Slide Number 60
- Slide Number 61
- Slide Number 62
- Slide Number 63
- Slide Number 64
- Slide Number 65
- Slide Number 66
- Slide Number 67
6
Connecting the Regulator to the LP Tank
1. The LP tank must be properly secured onto the grill. (Refer
to assembly section.)
2. Turn all control knobs to the OFF position.
3. Turn the LP tank OFF by turning the OPD hand wheel
clockwise to a full stop.
4. Remove the protective cap from the LP tank valve. Always
use cap and strap supplied with the valve.
Do not use household cleaning agents. Using Cleaning
agents can result in damage to the gas train
components (valve/hose/regulator).
Nipple has to be
centered into the
LP tank valve.
5. Hold the regulator and insert the
nipple into LP tank valve. Hand-
tighten the coupling nut, holding
the regulator in a straight line with
the LP tank valve so as not to
cross-thread the connection.
LP Tank Exchange
• Many propane retailers offer the option of replacing your
empty LP tank through an exchange service. Only use
reputable exchange companies that inspect, precision fill,
test and certify their tanks.
Exchange your tank only for an
OPD safety feature-equipped tank as described in the "LP
Tank" section of this manual.
• Always keep your new and exchanged LP tanks in the
upright position during use, transportation or storage.
• Leak test new and exchanged LP tanks BEFORE
connecting to the grill.
LP Tank Leak Test
• Leak test must be repeated each time a LP tank is
exchanged or refilled.
• Do not smoke during a leak test.
• Do not use an open flame to check for gas leaks.
• The grill must be leak tested outdoors in a well-ventilated
area, away from ignition sources such as gas or electrical
appliances. During the leak test, keep the grill away from
open flames or sparks.
• Use a clean paintbrush and a 50/50 mild soap and water
solution. Brush soapy solution onto areas indicated by
arrows in figure below. Leaks are indicated by growing
bubbles.
For your safety:
WARNING
If “growing” bubbles appear, do not
use or move the LP tank. Contact a LP
gas supplier or your fire department!
Safety Relief Valve
Strap and Cap
Type 1 outlet with
thread on the
outside
OPD Hand
Wheel
Do not insert a POL
transport plug (plastic part
with external threads) into
the type 1 valve outlet. It
will remove the Safety
relief valve feature.
(OFF Clockwise)