Water Heater User Manual

Installation Instructions (cont'd)
2. The convertible element is located behind the lower access
panel of the water heater. Remove the two screws securing
the access panel, and remove panel.
5. Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
3. Remove the insulation block to expose the opening.
6. The buss bar is labeled 5500 W. Place the buss bar over termi-
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3.
7. The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
4. Lower Element: Lift out the tab as shown to unclip the
terminal cover from the thermostat. The terminal cover can
now be removed from the thermostat.
Lift cut tab to until
term hal cover from
:hecrnostat.
TERMINAL COVER
CLIPPED TO THER-
LOWER THERMOSTAT _]
PLASTIC TABS ON
?BOTH SIDES OF
TERM1NAL COVER
HOLD IT IN
pLACE.
THERMOSTAT
BRACKET
.d_-TANK
-ELEMENT
8. Tighten terminals 2 and 3 to ensure proper electrical
connection.
AWARNING ]
Failure to tighten terminal screws can causea fire whichI
can result in DEATH, SERIOUS BODILY INJURY, OR|
PROPERTY DAMAGE. /
11