MSDS
Test Report
No. CANEC1100744601 Date: 16 Mar 2011 Page 2 of 4
Test Results:
:ID for specimen 1 CAN11-007446.001
"Button battery" :Description for specimen 1
Test Method (Reference) MDLResultUnitTest Item(s) Limit
Heavy metals in battery (2006/66/EC )
0.0020
Cadmium (Cd)
% (w/w)
Acid digestion method, ICP-OES N.D.
0.0010
-
Lead (Pb)
% (w/w)
Acid digestion method, ICP-OES N.D.
0.0010
2
Mercury (Hg)
% (w/w)
Acid digestion method, ICP-OES N.D.
0.0001
Note:
1. mg/kg = ppm, 0.1% = 1000ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
Remark:
According to the Article 21(3) of Directive 2006/66/EC, Battery, accumulator and button cell shall include the
chemical symbol Mercury when containing more than 0.0005% of Hg, the chemical symbol Cadmium when
containing more than 0.002% of Cd and the chemical symbol Pb when containing more than 0.004% of Pb.