Installation Guide

51035BLSL ASSEMBLY INSTRUCTIONS
If the pump fails to run:
• Check circuit breaker, or try a dierent outlet.
• Check tubing for kinks and obstructions.
• Clean out any algae buildup.
• Remove the front cover & impeller cover to access the impeller area.
Turn the rotor to ensure it is not broken or jammed.
With low ow rate, the pump will spew or “burp”:
• Check the water level to make sure the pump is completely
submerged, water should always be above the min ll line (not
all water features include min ll line).
If abnormal noise is heard during operation (with water):
• Disconnect the power supply and then remove the pump front
cover and impeller cover.
• Use hand to grip the impeller, gently pull the impeller/rotor
assembly out of the pump housing.
• Rinse the impeller/rotor assembly and the cavity with clean water.
If breakage or surface damage is found in the assembly contact
Customer Service for a part replacement.
Suction cup
Back cover
Pump housing
Tube
Rotor/Impeller
Impeller cover
Front cover
Flow regulator
PUMP SAFETY & TROUBLESHOOTING
To clean the pump
Unplug the pump from the electrical
outlet. Use a small soft brush or place it
under a water stream to remove debris.
To keep water clean
Periodically change water
to prevent algae buildup.