Operation Manual
38
A
P
D
B
230 V
PEN
L
1
(L
2
)
PE Earth
N Neutral
L Live
230 V
PEN
L
1
(L
2
)
PE Earth
N Neutral
L Live
Fig. 11.1
ELECTRICAL FEEDER CABLE CONNECTION
WARNING: The power supply cable must be connected only by an authorised service
agent in order to avoid a hazard.
If the power supply cable is damaged, it must be replaced only by an authorised
service agent in order to avoid a hazard.
To connect the feeder cable to the cooker it is necessary to:
• Remove the 2 screws that hold shield “A” behind the cooker.
• Open completely the cable clamp “D”.
• Insert the feeder cable into the cable save “P”. The supply cable must be of a suitable
size for the current requirements of the appliance; see the section “Feeder cable
specications”.
• Connect the phase, neutral and earth cables to terminal “B”accordingtogures11.1
and 11.2.
• Pull the feeder cable and block it with the cable clamp “D”.
• Re-mount shield “A”.
Note: The earth conductor must be left about 3 cm longer than the others.
POWER SUPPLY
230 V~ 50 Hz 4680 W
FEEDER CABLE SPECIFICATIONS
Type “H05RR-F”
3 x 2,5 mm
2