Operation Manual

44
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple ring (TR) 7,00
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Ø injector
[1/100 mm]
Ø injector
[1/100mm]
Auxiliary (A) 1,00 0,30 50 72 (X)
Semi-rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 115 (Y)
Triple ring (TR) 3,50 1,50 95 135 (T)
LUBRICATION OF THE GAS TAPS
• Incaseofdifcultyinthegastapsoperation,callService.
IMPORTANT
Allinterventionregardinginstallationmaintenanceoftheappliancemustbefullled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
GB
Cat: II 2H3+