Instruction Manual 120V
For future reference, please record the serial number of your
cook top here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
The supply must be from an individual grounded circuit that is protected by a circuit breaker
and rated per the specifications for the various models as shown in the table above.
2
!
Warning: If the electric power supply does not meet the
product specifications, consult with a licensed electrician
before proceeding with installation.
Max Connected Required Power Minimum
Kenyon Part # Model # Load Supply Input Wire Size
B41510 MED2 2600 Watts 120 VAC/22A/60Hz #12 AWG
B41515 MED2TL 2400 Watts 120 VAC/20A/60Hz #12 AWG
B41517 MED1 1200 Watts 120 VAC/10A/60Hz #12 AWG
B41601 CAR2 2400 Watts 120 VAC/20A/60Hz #12 AWG
B41605 CAR1 1200 Watts 120 VAC/10A/60Hz #12 AWG
B49510 ALP2LG 2600 Watts 120 VAC/22A/60 Hz #12 AWG
B49515 ALP2SM 2400 Watts 120 VAC/20A/60Hz #12 AWG
B49517 ALP1 1200 Watts 120 VAC/10A/60Hz #12 AWG