User Manual
10
A-13inchesmaximumdepthofoverheadcabinets
B-36inchesisminimumheightofcountertopaboveoor
C-Theminimumatcountertopsurfacethatthecooktopwillrest
upon must be equal to or greater than the overall cooktop
dimensions(refertothefollowingpageforoverallcooktop
dimensions).
D-30inchesminimumclearancebetweenthetopofthecooking
surfaceandthebottomofanunprotectedwoodormetalcabinetor
24inchminimumclearancewhenthebottomofthewoodormetal
cabinetisprotectedbynotlessthan1/4-inch-thickameretardant
millboardcoveredwithnotlessthanNo.28MSGsheetsteel,
0.015-inch-think stainless steel, 0.024-inch-thick aluminum or
0.020-inch-thick-copper.
E-1-inchminimumfrombacksplashofcountertoptoedgeofglass
(refertothefollowingpageforoverallcooktopdimensions).
FOR INSTALLATIONS IN CANADA: “Do Not Install Closer Than 1/2 Inch
(12mm)FromAnyAdjacentSurface”,andNE PAS INSTALLER A’MDINS DE 12MM
DETOUTE SURFACE ADJACENTE.
Warning: To eliminate the risk of burns by reaching over heated
surface units, cabinet storage space located above surface units
should be avoided. If cabinet storage is to be provided, the risk can
be reduced by installing a range hood that projects horizontally a
minimum of 5” beyond the bottom of the cabinets.
Avertissement : Pour éliminer les risques de brûlures lorsque quelqu'un tente d'accéder à
l'espace au-dessus de la surface de cuisson, évitez d'y installer toute armoire de rangement.
Si une armoire de rangement y est installée, les risques peuvent être réduits en installant une
hotte qui dépasse horizontalement d'au moins 10 cm (5 po) la partie inférieure des armoires.
!
Beforemakingthecountertopcutout,checkforclearance.Checktoseeifthecooktopwillclear
thefrontandsidewallsofthebasecabinet.Itisalsoimportanttoprovideenoughventilation.
Fig. A
Fig. B
Adequateventilationofthespacebelowthe
countertop must be provided to ensure
properoperationoftheinductioncooktop.
Theunitemploysaninternalfancooling
system that requires adequate air exchange
toenableittorunefciently.Heat
transferredfromthebottomoftheunit
during operation will overheat an improperly
ventilated area.
2 INCH (51mm) MINIMUM