Owner manual

The Kepco Models BOP 100-2ML and BOP 100-2DL have been modified from standard Kepco
Models BOP 100-2M and BOP 100-2D, respectively, to be stable handling inductive loads up
to 1 Henry.
INSTRUCTION MANUAL CORRECTIONS:
This modification makes the BOP more suitable for a wide variety of applications such as
motor testing, testing of magnetic components (coils, speakers, etc.), industrial applications
with inductive loads, driving CRT coils, cryogenic applications and powering correcting magnets
for medical imaging applications or particle accelerators. The unit is designed to operate in a
stable manner in Current or Current Limit Mode for loads up to 1 Henry. They are also stable
with any R-L series load combination.
All specifications of the unit in voltage mode are unchanged from the standard model. Spec-
ifications listed in Table 1 are for BOP 100-2ML and BOP 100-2DL in Current Mode. All other
specifications are identical to the standard BOP.
In current mode the bandwidth is reduced when operating with a resistive load. Correspond-
ingly, the rise and fall time of the unit is increased.
TABLE 1. BOP 100-2ML AND BOP 100-2DL SPECIFICATIONS
Bandwidth (DC to f-3dB)
Rise/Fall Time
(2)
Recovery at Step
Load Time Constant
(3)
Load Effect
Nominal Resistive Load
(4)
Resistive
Load, Nominal
Inductive
Load, 2mH
3.5 KHz 5.0 KHz 84
µS 250µS 47 ppm/Hz
NOTES:
(1) Specifications listed are for Current Mode. All other specifications are identical to the standard BOP.
(2) 10%-90%, short-circuit.
(3) Short-circuit - Nominal Resistive Load.
(4) Load effect increases nonlinearly with frequency from the typical 0.5 mA in DC- full scale (same as
the standard unit) with the average rate listed.
KEPCO®
THE POWER SUPPLIER™
MODIFICATION OF STANDARD
KEPCO MODEL BOP 100-2ML
KEPCO MODEL BOP 100-2DL
BOP 100-2ML/DL/-r3 031512
KEPCO, INC. z 131-38 SANFORD AVENUE z FLUSHING, NY. 11355 U.S.A. z TEL (718) 461-7000 z FAX (718) 767-1102
email: hq@kepcopower.com z World Wide Web: http://www.kepcopower.com

Summary of content (2 pages)