4.3 Connecting a Door Status Input
Each EntraGuard Silver controller is shipped with an installation kit including all necessary terminal blocks and transorbs.
One of these terminal blocks has a jumper across pins 1 and 2. This terminal block is designated for use on TB-4. If a door
switch is not used on the controller, this jumper prevents a continuous door open status alarm from being received by the
controller. If a door switch is used, simply remove this jumper and install the door switch leads.
Figure 6: Door Status Input Connections
4.4 Connecting a Request to Exit (RTE) Input
Figure 7: Request to Exit Input Connections