MS-3000Quick Start Guide
3.0 Connections
The MicroStar Reader does not require configuration; there are no switches or jumpers to set.
The MicroStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be
connected to an alternative host controller/alarm panel through an IntelliProx used in its
Wiegand input device mode. All connections needed to support the reader are made through the
reader's cable. Please consult the tables on pages 2 and 3 for specific connection instructions.
3.1 PXL-250 Connections
The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is
made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but
no connection is made to that pin).
Connecting to the PXL-250 – TB5 or TB6
Figure 2: PXL-250 Connections
Pin # Function Wire Color
1 Reader Antenna Blue
2 Beeper Green
3 Reader Power Red
4 Reader Ground Black
4 Shield Silver
5 Green LED Brown
6 Red LED White
7 no connection –