Quick Start GuideMS-3000
3.2 Design 5 PXL-100 Connections
The "A" reader connects to TB2, pins 14 through 19. The "B" reader to TB3, pins 20 through
25.
Connecting the PXL-100 – TB2 Connecting to the PXL-100 – TB3
Figure 3: Design 5 PXL-100 Connections
NOTE: Please contact customer support at Keri Systems for information regarding connecting
a Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its
power connection made at the middle of the left edge of the printed circuit board.
Pin # Function Wire Color Pin # Function Wire Color
14 Green LED Brown 20 Green LED Brown
15 Beeper Green 21 Beeper Green
16 Reader Power Red 22 Reader Power Red
17 Reader Ground Black 23 Reader Ground Black
17 Shield Silver 23 Shield Silver
18 Reader Antenna Blue 24 Reader Antenna Blue
19 Red LED White 25 Red LED White