Manual
Page 14
01816-100 Rev. E
1530 Old Oakland Rd., Ste 100 San Jose, CA 95112 U.S.A. (800)260-5265 (408)451-2520 Fax (408)441-0309
.
PXL-100:SMART ENTRY CONTROLLER
12) Cable and Wiring Requirements
(CONT)
Input Power
- 12VAC or 12VDC at the PXL-100. Allow for power drop over the length of the cable.
(Belden 8461 or equivalent)
Lock Power
- If using the PXL-100 lock power output do not run more than 500’. (Belden 8461 or
equivalent)
RS-232 Cable
- Four conductor shielded 22 AWG wire. Distances of more than 50’ are not
recommended. (Belden 9537 or equivalent, 22 AWG shielded cable, 7 conductor)
RS-485 Network Wiring -
2 twisted shielded pairs (one each data, and ground) is recommended.
(Belden 1419A or equivalent)
13) Serial Cable Configuration
Versions 3.0 firmware of later revisions must use the series 5000 cables for serial connections.
Pre-revision 3.0 units must use the 100 series cables. For pin outs of the 100 series cables, please
consult the tables below. 5000 series cables will be introduced in Summer, 1996.
Model # Guide to Cables and Series
KDP-104 Pin Out
KDP-105 Pin Out
KDP-106 Pin Out
KDP-107 Pin Out
Function 100 Series 5000 Series
PXL-100 to P C (25 Pin) KDP -104 KDP -5004
PXL-100 to Laptop (9 P in) KDP -105 KDP -5005
PXL-100 to Serial Printer KDP-106 KDP-5006
PXL-100 to M odem KDP -107 KDP -5007
PX L-100
(25 P in S ocke t) Color
P C
(25 P in S ocke t)
Pin 2
Green
Pin 3
Pin 3
Red
Pin 2
Pin 7
Black
Pin 7
Pin 8
White
Pin 20
PX L-100
(25 P in S ocket) Color
P C
(9 Pin Socket)
Pin 2
G reen
Pin 2
Pin 3
Red
Pin 3
Pin 7
Black
Pin 5
Pin 8
White
Pin 4
P X L -100
(25 Pin Socket) Color
P rin te r
(25 Pin Plug)
Pin 2
G reen
Pin 3
Pin 3
Red
Pin 2
Pin 7
Black
Pin 7
Pin 8
White
P in 20
PX L-100
(25 P in S ocket) Color
M o d e m
(25 Pin Plug)
Pin 2
G reen
Pin 2
Pin 3
Red
Pin 3
Pin 4
Brown
Pin 4
Pin 5
O range
Pin 5
Pin 7
Black
Pin 7
Pin 8
White
Pin 8
Pin 20
Blue
Pin 20