PXL-250 Tiger Controller NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation. Quick Start Guide This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing controllers. For comprehensive information regarding the PXL250 Tiger Controller, please refer to the Technical Reference (P/N 01836-004).
Quick Start Guide PXL-250 Tiger Controller 1.0 Specifications Unit Dimensions • PXL-250 controller PCB - 6.75 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors - (17.15 cm by 15.25 cm by 4.45 cm) • PXL-250 controller PCB with an SB-293 Satellite Board - 7.25 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors - (18.45 cm by 15.25 cm by 4.45 cm) • PXL-250 controller PCB with an LCD-1 Alpha/Numeric Display - 7.70 inches high by 6.
PXL-250 Tiger Controller Quick Start Guide Input Device Configuration - 3 Inputs • Door Sense normally closed • Request to Exit normally open • Global Unlock normally open, or Auxiliary RTE A-Door normally open 2.
PXL-250 Quick Start Guide PXL-250 Tiger Controller Wiegand Compatible Readers • five to seven conductor, shielded, stranded, wire – depending upon the Wiegand reader’s requirements • a minimum gauge of AWG 24 is required for data transfer with a 500-foot maximum run length per Wiegand specification1 Input and Output Connections • two conductor, stranded, AWG 22 (or a larger gauge) NOTE: The Lock Output relay may require a heavier gauge of wire depending upon the current demands of the lock and the length
PXL-250 Tiger Controller Quick Start Guide DO NOT • make modem phone line connections through PBX telephone switching systems - most modems are not compatible with PBX systems leading to disconnection problems with the modem • locate the PXL-250 controller near EMI sources - EMI sources can affect the performance of the controller • use switching power supplies - they are EMI sources • route network and reader cables beside power cables - transients on the power cables may be picked-up by network and reade
Quick Start Guide PXL-250 Tiger Controller 4.0 Refer to Figure 1 on page 1 for all wiring connections. 4.1 Terminal Blocks Figure 2: Connecting Wires and Removing Terminal Blocks NOTE: Screws on terminal blocks must be tightened securely. 4.2 PXL-250 Wiring Instructions Connecting the Earth Ground and the 12 VDC Power Figure 3: Earth Ground and 12 VDC Power Connections NOTE: TB2 is colored red to make it easier to tell it apart from the network connector.
PXL-250 Tiger Controller • • Quick Start Guide 4.3 Connecting a Keri Systems Proximity Reader to a PXL-250P The "A" reader is wired to TB5. The "B" reader is wired to TB6. Figure 4: Proximity Reader Connections 4.4 Connecting a Wiegand Compatible Reader to a PXL-250W The PXL-250W controller can be configured to accept input from single-line LED, dual-line LED, and Essex keypad Wiegand input devices (through the Doors™ software).
PXL-250 Quick Start Guide PXL-250 Tiger Controller Make the following connections for a single-line LED or Essex Keypad Wiegand device. • The "A" input device is wired to TB5. • The "B" input device is wired to TB6. Figure 5: Single-Line LED and Essex Keypad Wiegand Reader Connections Make the following connections for a dual-line LED Wiegand device. • The "A" input device is wired to TB5. • The "B" input device is wired to TB6.
PXL-250 Tiger Controller Connecting a Door Status Input Each PXL-250 is shipped with an installation kit including all necessary terminal blocks and transorbs. One of these terminal blocks has a jumper across pins 1 and 2. This terminal block is designated for use on TB-4. If a door switch is not used on the controller, this jumper prevents a continuous door open status alarm from being received by the controller. If a door switch is used, simply remove this jumper and install the door switch leads.
Quick Start Guide PXL-250 Tiger Controller 4.7 Connecting a General Purpose Input The general-purpose input is used in conjunction with the programmable input/output feature of the Doors access control software. There are three possible uses for the general-purpose input.
PXL-250 Tiger Controller Connecting an Alarm Output Relay Figure 11: Alarm Output Relay Connections 4.9 Quick Start Guide 4.8 Connecting a Fail-Safe Lock Output Relay 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com PXL-250 Figure 12: Fail-Safe Lock Output Relay Connections 01835-002 Rev. 4.
4.10 Connecting a Fail-Secure Lock Output Relay Figure 13: Fail-Secure Lock Output Relay Connections PXL-250 Quick Start Guide PXL-250 Tiger Controller 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.
PXL-250 Tiger Controller RS-485 Access Control Network Connection Quick Start Guide 4.11 PXL-250 Figure 14: RS-485 Network Connections 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.
Quick Start Guide PXL-250 Tiger Controller 4.12 Controller RS-232 Serial Port to PC Connection The controller’s RS-232 serial port (see Figure 1 on page 1) provides a communication link between the access control network and the host computer via one of two ways. • • A serial direct connect cable between master controller and host computer (see Section 4.12.1). Two modems making a remote connection between the master controller and host computer (see Section 4.12.2 on page 16 and Section 4.12.
PXL-250 Tiger Controller PC/DB-9F to PXL-250/DB-9M RS-232 Direct Serial Connection The Keri Systems part number for this cable is KDP-252. Quick Start Guide 4.12.1.1 Figure 15: PC/DB-9F to PXL-250/DB-9M RS-232 Direct Serial Connections 4.12.1.2 PC/DB-25F to PXL-250/DB-9M RS-232 Direct Serial Connection The Keri Systems part number for this cable is KDP-251.
PXL-250 Quick Start Guide PXL-250 Tiger Controller 4.12.2 Modem to Controller To make the connection between access control network and host computer you will use two cables: one between the host computer its modem (see Section 4.12.3 on page 18), and one between the master controller and its modem. If the modem has a female DB-25 connector, you must use a Keri Systems KDP-336 cable or create a cable according to the drawing in Section 4.12.2.1.
PXL-250 Tiger Controller Modem/DB-9M to PXL-250/DB-9M Serial Port Connection Quick Start Guide 4.12.2.2 Figure 18: Modem/DB-9M to PXL-250/DB-9M Serial Port Connection PXL-250 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.
PXL-250 Quick Start Guide PXL-250 Tiger Controller 4.12.2.3 Modem Adapter Cable Connection This adapter cable is provided, when needed, with a modem purchased from Keri Systems. Connect the adapter cable between the modem and the KDP-336 cable as shown in Figure 19. Figure 19: Modem/Adapter Cable/Controller Connection 4.12.3 Modem to PC Serial Connection Keri Systems does not provide this cable.
PXL-250 Tiger Controller Modem/DB-25M to PC/DB-9F PC Serial COM Port Connection Figure 20: Modem/DB-25M to PC/DB-9F PC Serial COM Port Connection 4.12.3.2 Quick Start Guide 4.12.3.1 Modem/DB-25M to PC/DB-25F PC Serial COM Port Connection PXL-250 Figure 21: Modem/DB-25M to PC/DB-25F PC Serial COM Port Connection 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.
Quick Start Guide PXL-250 Tiger Controller 4.12.3.3 Modem/DB-9M to PC/DB-9F PC Serial COM Port Connection Figure 22: Modem/DB-9M to PC/DB-9F PC Serial COM Port Connection Modem/DB-9M to PC/DB-25F PC Serial COM Port Connection PXL-250 4.12.3.4 Figure 23: Modem/DB-9M to PC/DB-25F PC Serial COM Port Connection 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.
PXL-250 Tiger Controller Powering The Controller for the First Time NOTE: Verify the earth ground1 has been connected at pin 3 of TB-2 before turning the power on for the first time. NOTE: Do not connect the 12 VDC power supply’s terminal block output to the TB-2 connector on the PXL-250 controller until you have completed all the steps in section 5.1. 5.1 Verify the 12 VDC Supply Voltage To verify the 12 VDC supply voltage: 1. 2. 3. 4. 5. 6. 7. 8. 9.
Quick Start Guide PXL-250 Tiger Controller NOTE: Resetting the system RAM completely erases all information within the PXL-250 controller. If there is any information in system RAM from an access control installation and the system RAM is reset, the information in the controller is lost and cannot be recovered. 5.4 Viewing the Controller's Address To view the controller's address, click S1. The controller's address will appear on the address display for 2 to 3 seconds. 5.
PXL-250 Tiger Controller Reader Responses to Access Control Events During day-to-day activity, the reader will respond to access control events in a specific manner. Table 3 provides a summary of the reader's LED and beeper actions during access control events.
Quick Start Guide PXL-250 Tiger Controller 6.1 Normally-Closed A normally closed input device continually keeps a circuit active or complete. A state change is generated when the normally closed input device is forced open, breaking the circuit. In an access control system, a door switch is a typical example of a normally closed device. While the door remains closed, the switch remains closed. When someone opens the door, the door switch is opened, breaking the circuit and generating a state change.
PXL-250 Tiger Controller Quick Start Guide This page is intentionally left blank. PXL-250 1530 Old Oakland Road, Suite 100 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com 01835-002 Rev. 4.