WirnetTM iFemtoCell-evolution LoRaWAN® gateway for the Internet of Things Quick Start Guide Thank you for choosing Kerlink. We are proud to be part of your project.
1. Need help? • • • In order to provide the most updated technical documentation, as well as considering and saving the environmental resources, Kerlink is providing preferably “Online documentation”. Kerlink is gathering all the technical information on a Wiki: http://wikikerlink.fr/ ͳͳ If you don’t have yet your Wiki login/password please request them to support@kerlink.com (note that the “Product ID” of one of your products will be required).
- Application Notes: for questions related to generic engineering rules (Q1 2020) � AN-KLK03355 - Improving radio coexistence performance of LoRaWAN gateways � AN-KLK03356 - LoRaWAN gateways coverage optimization � AN-KLK03357 - LoRaWAN gateways installation recommendations � AN-KLK03358 - LoRaWAN gateways lightning protection • For any Warranty or Maintenance related request (Trouble shooting, help …) ͳͳ If purchased from a Distributor, please contact the distributor directly for Level1 support ͳͳ If
1 6 14 9 7 5 8 4 11 2 10 3 15 12 N° 1 Components 13 N° Components Wirnet™ iFemtoCell-evolution 9 SMA connector for LoRa antenna 2 Silkscreened KERLINK marking 10 Reset push button 3 Jack connector (for power supply 12Vdc 0,5A) 11 Silkscreened Reset marking 4 USB-A connector for configuration 12 USIM connector 5 RJ45 connector (Ethernet) 13 USB-C connector for debug probe and for configuration 6 3 bicolor LEDs 14 LoRa antenna (862-873MHz, 902-928MHZ, 3dBi, 50Ω; vertical
. Markings Symbol Description Wirnet iFemtoCell-evolution Type of equipment QR Code Power supply information CE marking indicating that the product complies with current European directives or other marking marking depending on the country 12V Symbol 0,5mA or other marking Board ID Serial number of board Final product ID Serial number of product MAC ADDR MAC address EUI Extended Unique Identifier IP 30 Indice of protection Description Marking indicating that the product complies with R
.2 Setting connections Before setting all connections, ensure that the power supply is not connected to the mains supply. An external LoRa antenna is connected to SMA or RP SMA connector. A 4G/3G antenna is integrated.
The Ethernet cable is not provided and must consist of two RJ45 T 568A (or 568B) plugs on each side. KERLINK recommends using a cable with the following characteristics: • Category: 6A • Shielding: STP (U/FTP) or SSTP (S/FTP) • Section conductors: AWG26 • External jacket: LSZH or PUR • Maximum length: 100 meters The power supply jack connector supply is not provided. Please check accessories preconized by Kerlink Operating temperature range: -20°C to +55°C Humidity: 5% to 95% Altitude max. < 2000m 6.
Applicative software means embedded software running on the Wirnet™ iFemtoCell-evolution like KERLINK Small Private Network (SPN) or Kerlink « common » packet forwarder or any another Packet Forwarder (software that forwards LoRa packets received to a server). Please contact your reseller to know the LEDs behavior if the applicative software installed on the Wirnet™ iFemtoCell-evolution is not the one officially provided by KERLINK.
password such as root/root, default password is built using the last 6 digits of the serial number, of CPU module ID for Wirnet iBTS and « board ID » for Wirnet iFemtoCell, iFemtoCell-evolution and Wirnet iStation: pdmk-$serialno. For example, if the serial number of a CPU module is 641ATe0507DD, then the root password will be pdmk-0507DD (case sensitive). This 6 digits number can also be retrieved in the hostname.
7.2 Wirnet™ iFemtoCell-evolution 915 The Wirnet™ iFemtoCell-evolution 915 will be compliant with both FCC and IC regulations The associated FCC and IC identifiers of the Wirnet™ iFemtoCell-evolution 915 are: Model: Wirnet™ iFemtoCell-evolution 915 FCC ID: 2AFYS-KLKFEVO915 IC: 20637-KLKFEVO915 Model: EG25G Contains FCC ID: XMR201903EG25G Contient IC: 10224A-201903EG25G The power supply of the Wirnet™ iFemtoCell-evolution 915 must be a limited source of power.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
8. Disposal / recycling Do not dispose of the product with household waste. For proper disposal, contact a waste disposal company. The product packaging (cardboard and liners) can be removed with used paper. 9. Warranty Contact your reseller for warranty conditions of the Wirnet™ iFemtoCell-evolution. The Wirnet™ iFemtoCell-evolution is not warranted by Kerlink in case the enclosure is opened, modified, painted, branded out, outligned by CUSTOMER for any reason.