Table 2: Required adjustment weights for interconnected bulk scales
1. Counting systems with reference scales KERN CFS 300-3, CFS 3K-5
6 kg 15 kg 30 kg 60 kg 150 kg 300 kg 600 kg 1500 kg 3000 kg
load 1
(1/5 Max)
1 kg 3 kg 5 kg 10 kg 30 kg 60 kg 100 kg 300 kg 600 kg
load 2
(1/3 Max)
2 kg 5 kg 10 kg 20 kg 50 kg 100 kg 200 kg 500 kg 1000 kg
load 3
(2/3 Max)
4 kg 10 kg 20 kg 40 kg 100 kg 200 kg 400 kg 1000 kg 2000 kg
load 4
(max)
6 kg 15 kg 30 kg 60 kg 150 kg 300 kg 600 kg 1500 kg 3000 kg
load 0
0 kg 0 kg 0 kg 0 kg 0 kg 0 kg 0 kg 0 kg 0 kg
load 4
(max)
6 kg 15 kg 30 kg 60 kg 150 kg 300 kg 600 kg 1500 kg 3000 kg
load 3
(2/3 Max
4 kg 10 kg 20 kg 40 kg 100 kg 200 kg 400 kg 1000 kg 2000 kg
load 2
(1/3 Max)
2 kg 5 kg 10 kg 20 kg 50 kg 100 kg 200 kg 500 kg 1000 kg
load 1
(1/5 Max)
1 kg 3 kg 6 kg 10 kg 30 kg 60 kg 100 kg 300 kg 600 kg
2. Counting systems with reference scale KERN CFS 50K-3
150 kg 300 kg 600 kg 1500 kg 3000 kg
load 1
(1/3 Max)
50kg 100kg 200kg 500kg 1000kg
load 2
(2/3 Max)
100kg 200kg 400kg 1000kg 2000kg
load 3
(max)
150kg 300kg 600kg 1500kg 3000kg
For counting systems with reference scale CFS 6K0.1, CFS 15K0.5 or
CFS 30k0.5, linearization of the bulk scales is impossible.