Manual

Chapter 5 Serial Communication
90
5
Online test ON
Command: #TEST1
Response: OK
Online test OFF
Command: #QUIT
Response: OK
Online test check
Command: #TEST
Response: #TESTn
n = 0: Online test OFF
1: Online test ON
Command: BCLR
Response: OK
Command: SSET
Response: OK
Laser off
Command: LOCK
Response: OK
Resetting Laser off
Command: UNLOCK
Response: OK
When the Laser off command is executed, bar code read operation (laser
emission) is disabled until the Laser off command is reset by using UNLOCK
command.
The Laser off command is retained even after the power is turned off.
Command: RESET
Response: OK
Online test mode
Sets to online test mode (
see P. 60
).
Clearing transmission buffer
Clears data stored in the transmission buffer.
Shift to setting mode
Enters the setting mode (
see P.4
).
Laser off/Resetting Laser off
Turns off the laser emission when the laser beam may cause injury to an operator
(
see P.2)
.
Reset
Resets the BL-700 software.