Chapter 5 Serial Communication
94
5
Description of Parameter Setting Commands
Saving/Initializing Settings/Quitting Setting Mode
Setting Bar Code Type and Number of Readable Digits for Codes 1 to 4
The following describes the parameter setting commands for Codes 1 to 4.
Be sure to send “Bar code type setting command” first before setting other param-
eters.
* When “Bar code type setting command” is newly sent, all other parameters for
the specified code will return to the default settings.
In this case, set all other parameters again.
Setting change commands and setting confirmation commands are described on
the following pages.
Function Command Response Description Error
being sent code
Saves settings in SAVE OK See page 92.
the EEP-ROM.
Initializes settings. DFLT OK Returns to the default-settings, 00, 05,
and saves the settings in the 14, 15
EEP-ROM.
Quits the setting SEND OK See page 92.
mode.
Function Command being Response Description Error
sent code
Change CODEm=n OK m=0 to 3:Codes 1 to 4 00, 01,
Confirm CODEm mn n=0: CODE 39 03, 05,
1: ITF 08, 14
2: Industrial2of5
3: Codabar
4: UPC/EAN
5: CODE128
6: COOP2of5
7: None
8: CODE93
Change MAXm=nn OK m=0 to 3: Codes 1 to 4 00, 01,
Confirm MAXm mnn nn=01 to 32 03, 04,
* For CODE39, 05, 09,
Codabar: 03 to 32 14
* For ITF: 02 to 32
* For CODE128:
01 to 64
Change MINm=nn OK
Confirm MINm mnn
Change WCm00n OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm RCm00 00n n=0: Disable 03, 04,
1: Enable 05, 07,
Change WCm01n OK m=0 to 3: Codes 1 to 4 14
Confirm RCm01 01n n=0: Disable
1: Enable
Setting bar code
type for codes 1 to
4.
Setting Max. No. of
readable digits
Setting Min. No. of
readable digits
Note: With EAN code,
this command causes
error.
CODE39 Sending
start/stop charac-
ter.
CODE39 Inspec-
tion of check digit
(Modulus 43)