Manual

Chapter 5 Serial Communication
96
5
Function Command being Response Description Error
sent code
Change WCm42n OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm RCm42 42n n=0: Disable 03, 04,
1: Enable 05, 07,
Change WCm43n OK m=0 to 3: Codes 1 to 4 14
Confirm RCm43 43n n=0:Output in 13 digits
1:Output in 12 digits
Change WCm44n OK m=0 to 3: Codes 1 to 4
Confirm RCm44 44n n=0: Disable
1: Enable
Change WCm51n OK m=0 to 3: Codes 1 to 4
Confirm RCm51 51n n=0: Disable
1: Enable
Change WCm83n OK m=0 to 3: Codes 1 to 4
Confirm RCm83 83n n=0: Disable
1: Enable
Change WCm84n OK m=0 to 3: Codes 1 to 4
Confirm RCm84 84n n=0: Forward
1: Reverse
Change WCm85nn OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm RCm85 85nn nn=01 to 32 03, 04,
: Effective digits 05, 09,
Change WCm86nn OK m=0 to 3: Codes 1 to 4 14
Confirm RCm86 86nn nn=01 to 32
: Starting digit
Change WCm81n OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm RCm81 81n n=0: Disable 03, 04,
1: Enable 05, 07,
Change WCm82n OK m=0 to 3: Codes 1 to 4 14
Confirm RCm82 82n n=0: Forward
1: Reverse
EAN/UPC(A•E)
Reading JAN 13
digits
EAN/UPC(A•E)
No. of UPC-A
output digits
EAN/UPC(A•E)
Adding “0” to UPC-
E system code
CODE128 Checking
double character
start pattern
See p. 32.
Setting max. code
length output
function
Setting direction for
max. code length
output
Setting effective
digits for max. code
length output
Setting starting digit
for max. code
length output
Setting label
orientation speci-
fied reading
Setting orientation
for orientation-
specified reading