Function Command being Response Description Error
sent code
Setting signal type
Change WP05n OK n=0: Level
Confirm RP05 05n 1: One-shot
Change WP42nnn OK nnn=001 to 225
Confirm RP42 42nnn (by 100 ms step)
Change WP04n OK n=0: 2 ms 00, 02,
Confirm RP04 04n 1: 10 ms 05, 07,
14
Change WP03n OK n=0: Normal-open
Confirm RP03 03n 1: Normal-close
Change WP06n OK n=0: Disable
Confirm RP06 06n 1: Enable
Change TRGTn OK N=1: Reading rate 00, 02,
Confirm TRGT TRGTn check mode 05, 08,
2: Tact check mode 14
Change TESTn OK n=0: Reset
Confirm TEST TESTn 1: Reading rate
check mode
2: Tact check mode
Change WP56hhh... OK hhh...=Trigger on 00, 02,
Confirm RP56 56hhh... command (Up to 8 05, 11,
characters) 14
* Specify characters
in HEX (hexadecimal)
code.
Change WP57hhh... OK hhh...=Trigger off
Confirm RP57 57hhh... command (Up to 8
characters)
* Specify characters
in HEX (hexadecimal)
code.
Setting one-shot
input time
Setting time
constant of trigger
input
Setting state of
trigger input
Starting test mode
when trigger input
turns on. (To
specify the test
mode, use the
command below.)
Specifying the test
mode to be started
when trigger input
turns on.
Starting test mode
when power is
turned on.
Setting characters
of trigger on
command
Setting characters
of trigger off
command
To set characters of the trigger on/Off command, send the following command.
Example 1
Change the trigger on command to S.
WP5653
* S=53h
Tips
S
00, 02,
05, 07,
14
00, 02,
05, 09,
14