Manual

Chapter 5 Serial Communication
102
5
Utility Setting (Stability LED, OK/NG output duration, Preset data for
compare)
To register the preset data, send the following command.
Example
Register “ABC123” as preset data.
WP68ABC123
Tips
Function Command being Response Description Error
sent code
Change WP09n OK n=0: Disable
Confirm RP09 09n 1: Enable
Change WP40nnn OK nnn= 001 to 255
Confirm RP40 40nnn (by 10 ms step)
Change WP68aaa... OK aaa...= Preset data
Confirm RP68 68aaa... (Up to 32 characters)
* For CODE128,
see P.136 to 137.
* To delete the
preset data, send
WP68.
Indication of
Stability LED
Setting OK/NG
output duration
Registration of
preset data for
compare
00, 02,
05, 07,
14
00, 02,
05, 09,
14
00, 02,
05, 12,
13, 14,
17, 18