Chapter 6 PCL Link
6
6.3 Device Assignment
The data areas used to control the BL-700 are provided in the PLC’s internal
memory (D areas or DM areas).
When a device head address is specified on the “PLC SETUP” screen in the BL-
700 setup software, the device numbers are automatically assigned based on the
specified head address.
Data memory head address
[Specified head address] +00 indicates the area where the bar code data is stored.
[Specified head address] +01 to +03 are reserved areas and cannot be assigned
for the bar code data.
[Specified head address] +04 to +06 are the areas used by the PLC to send a
reading trigger to the BL-700. The method for using the areas varies depending on
the BL-700 scan method, “Level signal trigger” or “One-shot signal trigger”. These
areas are not assigned if you set “Reading trigger input area” to “Disable” in the
BL-700 setup software. (In this case, these areas can be used for other purposes.)
When using the BL-700 in multi-label read mode 3, addresses +00 to +03 are used
as the data memory head addresses for Codes 1 to 4, respectively. Data is not
stored in the areas for which the code type is not set.
Address Description Reference page
+00 Data memory head address for Code 1 P.111
+01 Reserved area for Code 2 P.111
+02 Reserved area for Code 3 P.111
+03 Reserved area for Code 4 P.111
+04 Reading trigger area P.111 to 113
+05 Reading trigger response area
* Only when “Level signal trigger” is selected.
+06 One-shot trigger time setup area
* Only when “One-shot signal trigger” is selected.