Chapter 6 PCL Link
6
6.5 Communication Time
Time required data transmission
The time required for data transmission from the BL-700 to the PLC is as follows:
This communication time may change depending on the PLC's scan time and the
model of the PLC.
* When the RS-232C communication baud rate is 9600 bps:
Communication time to start reading using reading trigger area
To control the BL series’ reading operation using the reading trigger area, enter the
trigger ON command on the PLC, and obtain the time duration until the command
is received by the BL-700.
* When the RS-232C communication baud rate is 9600 bps:
Number of data digits MELSEC-A SYSMAC-C KV (KV mode)
10 Approx. 220 ms Approx. 330 ms Approx. 440 ms
20 Approx. 270 ms Approx. 380 ms Approx. 680 ms
32 Approx. 320 ms Approx. 460 ms Approx. 920 ms
MELSEC-A SYSMAC-C KV (KV mode)
Approx. 60 ms Approx. 80 ms Approx. 30 ms