Manual

Chapter 3 Functions for Reading Operation
47
3
Code type add function
Adds the bar code type before the readout data .
Label orientation add function
Adds the orientation of bar code travel before the readout data.
* If an read error occurs, this information is not added.
Order of additional information
If you select to include all the additional information functions, they appear in the
following order:
You can change the delimiter as desired (one character), except the delimiter of the scan
count.
Readout datat
:
Delimiter
t = 0 : CODE39
1: ITF
2: Industrial 2of5
3: Codabar
4: EAN/UPC (A•E)
5: CODE 128
6: COOP 2 of 5
7: Read error
8: CODE93
Readout datar
:
Delimiter
4 9000000
4 9000000
Reverse
orientation
LASER ON
STB
OK/NG
TIMING
TEST
BL-700
Forward
orientation
r = F : Forward
R: Reverse
Code type
Readout
data
Scan
count
Decode
match count
Label
orientation
::::
Tips