Chapter 4 Installing the Setup Software
4
3. Enter the “Read error code” from the keyboard. The code can be changed as
desired (within 8 characters).
Normally, the initial setting (ERROR) should be used as provided.
If a blank is specified for the setting, the BL-700 will not send the read error
code.
4. Click “Trigger input setting” to set the trigger input.
Read mode P.35 to 38
Data transmission trigger P.34
Double reading prevention time P.35 to 36
Decoding match count P. 32
Additional data function P.48 to 49
Read error code P.89
Trigger input setting
Set the trigger input, scanning method and trigger ON/OFF command.
1. For the scanning method, select either “Level signal trigger” or “One-shot signal
trigger”. If “One-shot signal trigger” is selected, the scanning time setting menu
also appears.
Set the scanning time to a number from 1 to 255 (100 ms to 25.5 s).