Instruction Manual

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
3-3 Cyclic communication
3-20
3
Communicating with the LJ-V7000 Series
The data to the measuring instrument is assigned to the OUT area of the EtherNet/IP
scanner.
Control Data (62 Words (124 Bytes)) assembly instance (Instance ID): 65H
For details on each parameter, refer to "Parameter List" (Page 3-22).
Assignment to OUT Area (Scanner to CB-EP100)
CB-EP100 data
Scanner's OUT area
Address 0
Address 1
Address 123
External Input
(Assembly Instance: 101)
1-byte (8-bit) data
Name
Address
(Byte)
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
Error clear
request
0 Reserved for system
Error clear
request
1 Reserved for system
Reserved
for system
2
-
11
Reserved for system
Timing
request
12
Timing
request
OUT8
Timing
request
OUT7
Timing
request
OUT6
Timing
request
OUT5
Timing
request
OUT4
Timing
request
OUT3
Timing
request
OUT2
Timing
request
OUT1
13
Timing
request
OUT16
Timing
request
OUT15
Timing
request
OUT14
Timing
request
OUT13
Timing
request
OUT12
Timing
request
OUT11
Timing
request
OUT10
Timing
request
OUT9
Auto-zero
request
14
Auto-zero
request
OUT8
Auto-zero
request
OUT7
Auto-zero
request
OUT6
Auto-zero
request
OUT5
Auto-zero
request
OUT4
Auto-zero
request
OUT3
Auto-zero
request
OUT2
Auto-zero
request
OUT1
15
Auto-zero
request
OUT16
Auto-zero
request
OUT15
Auto-zero
request
OUT14
Auto-zero
request
OUT13
Auto-zero
request
OUT12
Auto-zero
request
OUT11
Auto-zero
request
OUT10
Auto-zero
request
OUT9
Reset
request
16
Reset
request
OUT8
Reset
request
OUT7
Reset
request
OUT6
Reset
request
OUT5
Reset
request
OUT4
Reset
request
OUT3
Reset
request
OUT2
Reset
request
OUT1
17
Reset
request
OUT16
Reset
request
OUT15
Reset
request
OUT14
Reset
request
OUT13
Reset
request
OUT12
Reset
request
OUT11
Reset
request
OUT10
Reset
request
OUT9
External
input
request
18 Reserved for system
Storage
stop request
Storage
start request
Batch
end
request
Batch
start
request
Trigger
request
19 Reserved for system
Memory
clear
request
Reserved
for system
Reserved
for system
20
-
27
Reserved for system