Instruction Manual
- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
3-4 Message Communication
3-68
3
Communicating with the LJ-V7000 Series
0EH CC0H device name Indicates the device name. R STRING
CC1H
-
CE3H
Reserved
0EH
CE4H Product code
Stores the product code of the mea-
suring instrument.
RINT
CE5H Revision
Stores the revision.
USINT[0]: Major revision
USINT[1]: Minor revision
R
struct of
USINT[2]
CE6H Controller model
Indicates the measuring instrument
model.
RSTRING
CE7H Series code Indicates the series code. R INT
CE8H Series version Indicates the series version. R INT
CE9H Device type Indicates the device type. R INT
CEAH Reserved
0EH
CEBH
Connected head
model [0]
Indicates the head model. R STRING
CECH
Connected head
model [1]
Indicates the head model. R STRING
CEDH
-
CF9H
Reserved
0EH
CFAH
Connected unit
model [0]
Indicates the connected unit model. R STRING
CFBH
Connected unit
model [1]
Indicates the connected unit model. R STRING
CFCH
-
CFFH
Reserved
4BH None Program switch
Specifies the number of the program
to change to.
WUDINT
4CH None Error clear Clears errors - -
4EH None
Request to reflect
setting write area
Specifies the reflection destination
area.
WUDINT
4FH None
Update of setting
write area
Specifies Update source area. W UDINT
50H None
Initialize specified
program number
settings
Program number W UDINT
57H None
Profile data con-
firmed
Copies the latest profile data to the
areas that can be acquired with the
attribute IDs 370H to 39FH.
RUDINT
58H None Daily settings Date and time information W
struct of
UDINT[7]
59H None
Acquires date
and time
Date and time information in service
response
R
struct of
UDINT[7]
5FH None
Initializes all set-
tings
Returns the all settings to their default
values.
--
Service
code
(hexadecimal)
Attribute
ID
(hexadecimal)
Name Description and service data
Attribute