Owner manual

KEYENCE CORPORATION. Vision System Division
13 www.keyence.com
Command Processing Flow
To control the controller via PLCLink, use the numberspecified commands.
1
The command processing result is stored to the
address specified as the "Command Result Address".
Refer to "Control/Data Output via Commands" in the user's manual to check the commands to use and the
formats of the number-specified commands.
Here is an example of using the PW command (command No. 24) that switches the program setting.
The following must be specified to execute the PW
command:
Command No. (24)
SD card No. (d) of the switch target program setting
Setting No. (nnn)
Specify 2word integer values from the data memory
specified as the "Command Address" in order.