1. Establishing the PLC-Link (Ethernet PLC-Link) [YASKAWA MP Series]
Checking the Global Settings of the CV-X Series
Select [Global] > [Communications & I/O] > [Network] on the controller, and then configure the network
(Ethernet) settings for the CV-X.
2
Select "OK" to close the "Network Settings" screen, select [Global] > [Communications & I/O] > [PLC-Link], and
then configure the PLC-Link settings.
3
Select "OK" to close the "PLC-Link" setting screen and then restart the controller.
Configure the network settings for CVX.
IP Address: 192.168.1.10
* Change the IP Address according to the
default MP Series Network Settings.
Subnet Mask: 255.255.255.0
Default Gateway: 0.0.0.0
Configure the PLCLink settings.
Mode: PLC- Link (Ethernet)
PLC Type: YASKAWA MP Series
IP Address: Change to 192.168.1.1
Port: Change to 1024
Resend Time (ms): 10000
* "IP Address" above indicates the one for the
KV Series that will be connected. Set an address
whose fourth number differs from that of the
"Controller IP Address" set in step 1.
Decimal Point: Fixed- point
Command Execute Event: Polling
Command Complete Address (bit): 00003
Command Address: 00100
Command Result Address: 00200
Result Output Address: 00500
Result Ready Address (bit): 00000
Result Ack Address (bit): 00001
Acknowledge result output completion:
Checked
Enable Handshake: Unchecked
[Note] The memory range that can be used
with the MP Series communication
specifications is 0 to 4095.
This section describes how to establish the PLCLink.
[Important] If it fails, establish a one-to-one connection between PLC and CV-X, and follow this manual to configure the settings and check
the operations. Confirm that it operates properly, and change settings if necessary.
Be careful not to use the
same IP address.