Owner manual
KEYENCE CORPORATION. Vision System Division
‐ 8 ‐ www.keyence.com
6
Restart both the CV-X Series and the YASKAWA MP Series.
If "Initializing PLC- Link..." appears on the lower left of the screen and
disappears immediately, it indicates that the link has been established
successfully.
If the link establishment has failed, the message "Initializing PLC- Link...
*" appears repeatedly, and the error message "Failed to establish a link
with the PLC" appears.
Check the settings of the CV‐X and YASKAWA MP Series again.
* Start the YASKAWA MP Series first, and then start the CV‐X Series.
4
Use the screen below as a reference to set the communication settings.
5
Send the settings to PLC using [Online] > [Write into Controller] in MPE720.
Connect Protocol: MEMOBUS
Master/Slave: Slave
Device Address: 1
Serial I/F: RS-232C
Connect Mode: RTU
Data Length: 8 Bit
Parity Bit: even
Stop Bit: 1 Stop
Baud Rate: 115.2 K
Delay: Disable
Timer: Disable
Auto Receipt: Enable
About the RS‐232C cable that is used to connect
the CV‐X Series and the MP Series.
Alter OP‐26487 (2.5 m straight cable) and connect it to
the commercially available D‐sub 9 pin male connector
as shown in the figure below.
[]