3-4 Command Parameter List
3-31
3
Communicating with the FD-S series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
00
nn8F Hysteresis R/W
FD-SS02 001.0 000.0 to 200.0
FD-SF1(S) 0010 0000 to 1000
FD-SF1(F) 001.0 000.0 to 200.0
FD-SS2(S) 0010 0000 to 2000
FD-SS2(F) 001.0 000.0 to 200.0
FD-SF8(S) 00.10 00.00 to 08.00
FD-SF8(F) 0010 0000 to 2000
FD-SS20(S) 00.10 00.00 to 20.00
FD-SS20(F) 0010 0000 to 2000
nn90 Control InputR/W-
0
0: OFF
1: Bank change
2: Flow rate zero
3: Zero adjustment
4: Integration reset
nn91 to
nn96
System reserved
nn97 Power save mode R/W - 0
0: OFF
1: HALF
2: ALL
nn98 to
nn9C
System reserved
nn9D
Flow indicator
color
R/W - 1
0: Red for ON, green for OFF
1: Green for ON, red for OFF
nn9E
to nn9F
System reserved
nnA0
Group5 entry
count
R-8
nnA1 to
nnA2
System reserved
nnA3 Flow direction *11 R/W - 0
0: std
1: rEv
nnA4
Integrated flow
quantity unit ("A"-
free version)
R/W
FD-SS02
3
0: Cannot be set / 1: 0.1 / 2: 1 / 3: 10 /
4: 100 / 5: 1000 / 6: Cannot be set
FD-SS2
0: Cannot be set / 1: Cannot be set /
2:1 / 3:10 / 4: 100 / 5: 1000 / 6: 10000
FD-SS20
0: 0.01 / 1: 0.1 / 2: 1 / 3: 10 / 4: 100 /
5: Cannot be set / 6: Cannot be set
nnA5 to
nnA6
System reserved
nnA7
Select volume/
mass flow rate
*11 R/W - 1
0: Mass fl ow rate
1: Volume fl ow rate (specified density)
2: Volume fl ow rate (instantaneous
density)
nnA8 Specify focus *11 R/W - 0
0: OFF
1: ON
nnA9 to
nnBF
System reserved
nnC0
Group6 Entry
count
R-11
nnC1 Product Code R - -
FD-SA*A: Main unit: 4014
FD-SA*A: Expansion unit: 4015
FD-SA*: Main unit: 4012
FD-SA*: Expansion unit: 4013
nnC2 Revision R - - 0101h
Data
category
(HEX)
Data
number
(HEX)
Name
Description Attribute Sensor head
Default
value
Parameter range