User Manual
3-2 I/O Communication
3-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
3
Communicating with the GT-70A series
"3-output + current value" mode
5-output mode
"5-output + current value" mode
3-output + monitor
No extended mode Yes - - -
3-input - Yes Yes Ye s
Bank change - - Yes -
Setting value rewrite - - - Ye s
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor amplifi ers
1 14
0
20
6
24
10
28
24
2 18 24 28 32
3 22 28 32 36
4 26 32 36 40
5 30 36 40 44
6 34 40 44 48
7 38 44 48 52
8 42 48 52 56
9 46 52 56 60
10 50 56 60 64
(b
ytes)
5-output
No extended mode Yes - - -
5-input - Yes Yes Yes
Bank change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor amplifi ers 1-10 12 0 22 10 26 14 34 40
(bytes)
5-output + current value
No extended mode Yes - - -
5-input - Yes Yes Ye s
Bank change - - Yes -
Setting value rewrite - - - Ye s
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor amplifi ers
1 18
0
28
10
32
14
40
40
2 22 32 36 44
3 26 36 40 48
4 30 40 44 52
5 34 44 48 56
6 38 48
52 60
7 42 52 56 64
8 46 56 60 68
9 50 60 64 72
10 54 64 68 76
(bytes)