Installation and Connection to Sensor Amplifiers
๎ Number of Connectable Sensor Amplifiers
* Cannot be connected to GT-70 series.
This section describes how to mount the DL-EP1 on the DIN rail and to connect it to
sensor amplifiers.
Sensor amplifiers supporting D-bus are connectable. You can connect one sensor to
the DL-EP1 as a main unit and one or more sensors to the main unit as expansion
units. (D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers.)
If the sensor amplifier is D-bus compatible, different models can be connected
together.
How many and what types of sensor amplifiers can be connected depends on the
sensor amplifiers or units to be connected. Please inquire for details.
๎ Mounting the DL-EP1 on the DIN rail
1
Align the claw on the bottom of the DL-EP1 with the DIN rail. While
pushing the amplifier in the direction of arrow (1), press down in the
direction of arrow (2).
2
To remove the DL-EP1, raise the amplifier in the direction of arrow (3)
while pushing the DL-EP1 in the direction of arrow (1).
Name Amplifier form Main unit
Expansion
unit
Maximum number of
connectable units
GT-70A
Series*
DIN rail mount
type
GT-71A
GT-71AP
GT-72A
GT-72AP
10
(1 main unit, 9 expansion units)
Panel mount
type
GT-75A
GT-75AP
GT-76A
GT-76AP
10
(1 main unit, 9 expansion units)