3-4 Message Communication
3-24
3
Communicating with the GT-70A Series
(5) Reading the number of decimal places from a sensor amplifier
Message communication reads the number of decimal places of settings read
from the sensor amplifier.
"(5) Reading the number of decimal places in the parameter from a sensor
amplifier" (Page 3-50)
For the GT-70A Series, if the current value is 12.53 mm, data is stored as
follows:
Data: 12530
Number of decimal places: 3
Perform calculation from the read data and the number of decimal places.
If message communication writes data to a sensor amplifier, issues an
operation command to the sensor amplifier, or locks sensor amplifier
operations, the sensor amplifier button operations are locked for about 10
seconds. "COM-Lock ( )" is displayed for about 2 seconds during
switching to the locked state or when an attempt is made to operate a
locked button. When button operation is unlocked, "COM-Unlock
( )" is displayed for about 2 seconds.
Command
Response
DL-EP1
Scanner
<Details of command>
Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)
GT-7∗A
Reads the number of decimal places of
the GT-7∗A comparator value (P.V. value).
Reference
12530 12.530 12.53mm
Number of
decimal places
321
Point