User Manual
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT-70A) -
3-4 Message Communication
3-34
3
Communicating with the GT-70A Series
00H
75H
(117)
Output2
(LOW)
Indicates the LOW output (output 2) status of
each amplifier. When LOW is output, the bit
corresponding to the ID number of the sensor
amplifier is turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
76H
(118)
Output3
(GO)
Indicates the GO output (output 3) status of each
amplifier. When GO is output, the bit
corresponding to the ID number of the sensor
amplifier is turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
77H
(119)
Output4
(Unassigned)
(Unassigned)
R
WORD
78H
(120)
Output5
(Unassigned)
(Unassigned)
R
WORD
79H
(121) to
89H
(137)
Reserved for system
8AH
(138)
Current
Value 0
Invalid
When the current value 0 of each amplifier is
invalid, the bit of corresponding ID number is
turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
8BH
(139)
Current
Value 0
Under Range
When the current value 0 of each amplifier is less
than the lower limit of the detection range,
the bit
of the corresponding ID number is turned ON
.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
8CH
(140)
Current
Value 0
Over Range
When the current value 0 of each amplifier is
higher than the upper limit of the detection range,
the bit of corresponding ID number is turned ON
.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
8DH
(141)
Current
Value 1
Invalid
When the current value 1 of each amplifier is
invalid, the bit of the corresponding ID number is
turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
8EH
(142)
Current
Value 1
Under Range
When the current value 1 of each amplifier is less
than the lower limit of the detection range, the bit
of the corresponding ID number is turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
8FH
(143)
Current
Value 1 Over
Range
When the current value 1 of each amplifier is
higher than the upper limit of the detection
range, the bit of the corresponding ID number is
turned ON.
Bit 0 to bit 9: ID number 1 to ID number 10
Bit10 to bit 15: Reserved for system
R
WORD
Instance
ID
Attribute
ID
Name Description
Attribute
Data
Ty p e