- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT-70A) -
● Attributes for GT-70A Series (Common to all GT-70A Series)
Designate the ID number (01H to 0AH) of a sensor amplifier as the instance ID.
Class
Attribute
ID
Name Description
Attribute
Data
Ty p e
Group1
0320H
(800)
Group1
Entry count
Indicates the number of items (entries) that can
be set in Group 1.
Parameter range: 9
RDINT
0321H
(801)
Sensor
amplifier
error state
*1
Indicates the error status of the sensor amplifier.
bit0: Overcurrent error (ErC)
bit1: Head error (ErH)
bit2: EEPROM error (ErE)
bit3: Jam check error (Er.chK)
bit4: Self-timing delay (Er.dLY)
bit5: Number-of-units error (Er.Unit)
bit6: Calculation error(Er.CAL)
R
DWORD
0322H
(802) to
0323H
(803)
Reserved for system
0324H
(804)
Control
output
*2
Indicates the control output status.
Parameter range: 00H to 1FH (initial value: 00H)
bit0: HIGH output
bit1: LOW output
bit2: GO output
R
DWORD
0325H
(805)
Comparator
value (P.V.
Value)
*3, *4, *5
Indicates the comparator value (P.V. value).
Parameter range:
-99.9999 to 999.9999
RDINT
0326H
(806)
Raw value
(R.V. Value)
*
3,
*
4
Indicates the raw value (R.V. value).
Parameter range:
-99.9999 to 999.9999
RDINT
0327H
(807)
Peak value
during
sampling
*
3,
*
4,
*5, *
6, *7
Indicates the peak value during sampling.
Parameter range: -99.999 to 999.999
RDINT
0328H
(808)
Bottom value
during
sampling
*
3,
*
4,
*5, *
6, *7
Indicates the bottom value during sampling.
Parameter range: -99.999 to 999.999
RDINT
03
29H
(8
09)
Calculation
display
value
*3, *4, *8
Indicates the calculation display value.
Parameter range: -99.999 to 999.999
RDINT