User Manual
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT-70A) -
3-4 Message Communication
3-40
3
Communicating with the GT-70A Series
Group4
0382H
(898)
Detection
mode
Indicates detection mode.
Parameter range: 0 to 4 (initial value: 0)
0: Standard
1: NG hold
2: Peak hold
3: Bottom hold
4: Peak-to-peak
R/W DINT
0383H
(899)
Reserved for system
0384H
(900)
Response
time
*13
Indicates the response time.
Parameter range: 0 to 6 (initial value: 3)
0: HSP (1.5)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
6: 5000 ms
R/W DINT
0385H
(901)
Timing
type
*14
Indicates the timing type.
Parameter range: 0 to 2 (initial value: 0)
0: External timing input
1: Rising edge self-timing
2: Falling edge self-timing
R/W DINT
0386H
(902)
Self-timing
level
Indicates the self timing level.
Parameter range: 199.9999
-99.999 to 999.999 (initial value: 0.500)
R/W DINT
0387H
(903)
Self-timing
delay type
Indicates the self-timing delay type.
Parameter range: 0 to 1 (initial value: 0)
0: Static hold
1: Delay timer
R/W DINT
0388H
(904)
User-
specified
delay time
Indicates the user-specified delay time.
Parameter range: 0 to 9999
(initial value: 1000)
R/W DINT
0389H
(905)
Delay stable
determination
Sets the static hold delay stable determination.
Parameter range: 0 to 1 (initial value: 0)
0: Default
1: User
R/W DINT
038AH
(906)
Delay stable
range
Sets the static hold delay stable range.
Parameter range:
0.000 to 999.999 (initial value: 0.010)
R/W DINT
038BH
(907)
Measurement
direction
Sets the measurement increase/decrease
direction.
Parameter range: 0 to 1 (initial value: 0)
0: Normal
1: Reversed
R/W DINT
038CH
(908)
Multiplier
Indicates the multiplier.
Parameter range: 0.1 to 100.0
(Initial value: 1.0)
R/W DINT
038DH
(909)
Output mode
Indicates output mode.
Parameter range: 0 to 1 (initial value: 0)
0: N.O.
1: N.C.
R/W DINT
Class
Attribute
ID
Name Description
Attribute
Data
Ty p e