3-4 Diagnostic Function
3-13
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Executing Communication
3
Identifier-related diagnosis
Information to identify the unit where an error occurred is stored in Octet 7 to 10.
Module status
Error information is stored in Octet 11 to 19 when the hardware configuration on the
configuration software does not coincide with the actual configuration.
Octet Content bit Value
7
Length of the Identifier-related diagnosis
0
00 0100
B
(fixed) :
5
Code for Identifier-related diagnosis
6
01
B
(fixed)
7
8
BIT corresponding to the module where an error has occurred
is set.
(Slot 0 to 7)
0 Error in Slot 0 (DL-PD1)
::
7 Error in Slot 7 (Sensor amplifier)
9
BIT corresponding to the module where an error has occurred
is set.
(Slot 8 to 15)
0 Error in Slot 8 (Sensor amplifier)
::
7 Error in Slot 15 (Sensor amplifier)
10 Reserved
0
:
7
0000
B
Octet Content bit Value
11
Length of the Module status
0
00 1001
B
(fixed):
5
Code for Module status
6
00
B
(fixed)
7
12 Status Type module Status
0
130
D
(fixed):
7
13 Reserved
0
0 (fixed):
7
14 Reserved
0
0 (fixed):
7