Owner manual

1
E DL-PD1_IM
PROFIBUS DP Compatible Network Unit
DL-PD1
Instruction Manual
Read this manual before use.
Keep this manual in a safe place for future reference.
Symbols
The following symbols alert you to matters concerning the prevention of injury and product
damage.
General Precautions
Precautions for Use
Precautions for Installation
UL Certificate
This product is an UL/C-UL Listed product.
UL File No. E207185
Category NRAQ, NRAQ7
Be sure to consider the following specifications when using this product as an UL/C-UL
Listed Product.
Use the power supply with Class 2 output defined in NFPA70 (NEC: National Electrical
Code).
Use this product under pollution degree 2.
This product is an open type device. Therefore, it must be installed in an enclosure with
IP54 or higher. (e.g. Industrial control panel)
CE Marking
Keyence Corporation has confirmed that this product complies with the essential
requirements of the applicable EC Directive, based on the following specifications. Be sure
to consider the following specifications when using this product in the Member State of
European Union.
EMC Directive (2004/108/EC)
Applicable standard EMI: EN55011, Class A
EMS: EN61000-6-2
Remarks: These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of EMC Directive. The
manufacturer of the end-product is solely responsible for the compliance on the
end-product itself according to EMC Directive.
The DL-PD1 is an interface unit, which enables sensors to connect to the PROFIBUS DP.
The characteristics of the DL-PD1 are shown below.
Slave Unit of the PROFIBUS DP-V1
The following features are achieved by connecting the sensors, which are suitable
for each application, in the form of a module.
Reading out the Output of the sensor.
Reading out the measurement value of the sensor.
Changing the configuration of the sensor.
Two selectable operational modes
Monitor Mode: Input size – MAX 107 bytes, Output size – MAX 16 bytes
I/O Mode: Input size – 10 bytes, Output size – 10 bytes
Corresponding to the communication speed of 9.6 kbits/s to 12 Mbits/s
The DL-PD1 can connect to up to 15 units of sensor amplifiers (a single main unit and
multiple expansion units) which support D-bus. (“D-bus” is the name of KEYENCE’s
wiring-saving system for sensor amplifiers.)
Different types of sensor amplifiers with D-bus support can be connected to a single DL-PD1
unit.
How many and what types of sensor amplifiers can be connected depends on the sensor
amplifiers or units to be connected. Please inquire for details.
It indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
It indicates a situation which, if not avoided, could result in product
damage as well as property damage.
It indicates cautions and limitations that must be followed during
operation.
It indicates additional information on proper operation.
Safety Information for DL-PD1
Do not use this product for the purpose to protect a human body or
part of a human body.
This product is not intended for use as an explosion-proof product.
Do not use this product in a hazardous location and/or potentially
explosive atmosphere.
Before and while operating this product, confirm that it provides its
functions and performance correctly.
Implement sufficient safety measures to prevent human and
physical damages in case this product fails.
Do not expose equipment, including peripherals, to rapid
temperature changes. Equipment failure may result from
condensation build up.
Be aware that the product functions and performance are not
warranted if the product is used outside the range of stated
specifications or is modified by the customer.
Combining this product with other equipment requires sufficient
consideration because the proper functions and performance may
not be provided depending on the environment.
WARNING
CAUTION
NOTICE
Important
Point
WARNING
CAUTION
NOTICE
To avoid injury or failure, turn off the power immediately in the
following cases.
- Water or foreign matter entered the main unit.
- The case is broken, for example if it is dropped.
- Smoke or unusual smell is emitted from the product.
Use the correct power voltage. Failure to observe may result in
injury, or failure.
Do not disassemble or modify this product. Failure to observe may
result in injury.
Do not turn off the power while you are setting any item. Doing this
may cause loss of data settings.
For safe, trouble-free operation of this product, the product must not
be installed in the following locations:
- Humid, dusty, or poorly ventilated.
- Exposed to direct sunlight or heating source.
- Exposed to corrosive or flammable gases.
- Exposed directly to vibration or shock.
- Exposed to water, oil, or chemical splashes.
- Exposed to static electricity.
If this product is installed in a location near a noise source, e.g. power
source or high-voltage line, it may malfunction or fail. Take protective
measures, such as using a noise filter including a supplied ferrite core
or running the cables separately.
* Use a ferrite core for a power cable of a sensor amplifier with D-bus
support which supplies power for the unit (3 turns).
Precautions on Regulations and Standards
Characteristics of the DL-PD1
CAUTION
NOTICE
CAUTION
NOTICE
96M12255