Owner's manual

1-2
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IB) -
Before Using
1
1-1 Characteristics of the DL-PD1
The DL-PD1 is an interface unit, which enables sensor amplifiers or input units to
connect to the PROFIBUS DP. The characteristics of the DL-PD1 are shown below.
Slave unit of the PROFIBUS DP-V1
The following features are achieved by connecting the sensor amplifiers, which
are suitable for each application, in the form of a module.
Reading out the output of the sensor amplifier.
Reading out the comparator value (the measurement value) of the sensor
amplifier.
Changing the configuration of the sensor amplifier.
Two selectable operational modes
Monitor Mode: Input size - MAX 107 bytes, Output size - MAX 16 bytes
I/O Mode: Input size - 10 bytes, Output size - 10 bytes
Corresponding to the communication speed of 9.6 Kbits/s to 12 Mbits/s
System configuration example
Additional sensor amplifiers corresponding to the D-bus can be connected to the DL-
PD1. ("D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.)
Any sensor amplifiers corresponding to the D-bus allow different models and up to 15
units of sensor amplifiers to be connected simultaneously.
Connectable quantity depends on the sensor amplifier which is connected to.
PROFIBUS DP master
D-bus compatible sensor amplifier I/O etc.
DL-PD1