Owner's manual

3-6 DP-V1 Service
3-35
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IB) -
Executing Communication
3
157 Judgment indicator color DINT R/W 0
0: Green for GO only (Default)
1: Red for Go only
2: All green
3: All red
158 P.V. value display color DINT R/W 0
0: Green for GO only (Default)
1: Red for Go only
2: All green
3: All red
159 Reserved for system
160 Group5 Entry count DINT R 9
161 Save adjust state DINT R/W 0
0: OFF
1: ON
162 Adjust level DINT R/W 20 1 to 30
163 Auto adjust function DINT R/W 0
0: Disabled
1: Enabled
164 Auto adjust level DINT R/W 3.00 0.50 to 20.00
165 Check output function DINT R/W 0
0: Disabled
1: Enabled
166 Check output light level DINT R/W 10 1 to 30
167 Error output mode DINT R/W 0
0: Normal mode (Default)
1: LX2 compatible mode
168 Hysteresis for trigger level DINT R/W 0
0: Default
1: User setting
169
Hysteresis set value for
trigger level
*16 DINT R/W 1.00 0.00 to 999.99
170 to
191
Reserved for system
192 Group6 Entry count DINT R 11
193 Product code DINT R
Main unit:=4020
Expansion unit:=4021
194 Reserved for system
195 Transmitter head model DINT R
0:
Sensor head is not connected,
or light receiver is connected.
1: Light transmitter of IB-01 is
connected.
2: Light transmitter of IB-05 is
connected.
3: Light transmitter of IB-10 is
connected.
4: Light transmitter of IB-30 is
connected.
196 Receiver head model DINT R
0:
Sensor head is not connected,
or light transmitter is connected.
1: Light receiver of IB-01 is
connected.
2: Light receiver of IB-05 is
connected.
3: Light receiver of IB-10 is
connected.
4: Light receiver of IB-30 is
connected.
197 to
199
Reserved for system
200 Product name 1 *20
DINT/
STRING
R
Main unit:="IB-1"
Expansion unit:="IB-1"
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value