User guide

3-2
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IL) -
Executing Communication
3
3-1
PROFIBUS communication function of DL-PD1
This section describes the overview of the PROFIBUS DP communication functions the
DL-PD1 supports.
Overview
The DL-PD1 operates as a slave unit for PROFIBUS DP. The sensor amplifier output or
comparator value can be read via the cyclic communication, and the sensor amplifier's
external input ON/OFF can be controlled. Also, setting the DL-PD1 or sensor amplifier
connected to DL-PD1 and reading/writing the status of them are possible via the acyclic
communication of the DP-V1 service.
"Overview of PROFIBUS DP Communication" (page 3-17)
"DP-V1 Service" (page 3-26)
IN area
OUT area
Output
Judgment value
Error information
External Input
PROFIBUS DP
master
DL-PD1
Sensor amplifier
Output
Judgment value
・・・・・・
・・・・・・
Error information
Setting value
Exteral input
Output
Judgment value
・・・・・・
・・・・・・
Error information
Setting value
External Input
Cyclic
communication
Cyclic
communication
DP-V1 service
Output
Judgment value
・・・・・・
・・・・・・
Error information
Setting value
Exteral input
IN area
OUT area
Read/write parameters
・・・・・・
・・・・・・
・・・・・・