User Manual

3-6 DP-V1 Service
3-32
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -
Executing Communication
3
132 Response time DINT R/W 3
When the
connected
sensor head is
GT2-H***/A***
When the
connected
sensor head
is GT2-P***
0: HSP (3.0 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
HSP (12 ms)
20ms
40ms
400ms
2000ms
4000ms
133 Timing type DINT R/W 0
0: External timing input
1: Rising self
2: Falling self
134 Self-timing level DINT R/W +000.5000 -199.9999 to +199.9999
135 Self-timing delay type DINT R/W 0
0: Static hold
1: Delay timer
136 User-specified delay time DINT R/W 1000 0000 to 9999
137 Static hold determination DINT R/W 0
0: Default
1: User
138 Static hold stable range DINT R/W +000.0100 000.0000 to +199.9999
139 Measurement direction DINT R/W 0
0: Normal
1: Reverse
140 Multiplier DINT R/W 001.0 000.1 to 100.0
141 Output mode DINT R/W 0
0: NO
1: NC
142 Display resolution DINT R/W 0
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
143 Hysteresis DINT R/W +000.0030 000.0000 to +199.9999
144 Simultaneous input setting *12 DINT R/W 0
0: Individual input
1: Simultaneous input
145 Special output setting *8 DINT R/W 0
0: Do not use
1: 5-output
2: Limit output
3: Limit output user setting
4: All GO
5: All limit output
146 Limit output HH position *8 DINT R/W 000.0000 -199.9999 to +199.9999
147 Limit output LL position *8 DINT R/W 000.0000 -199.9999 to +199.9999
148 Select preset data DINT R/W 0
0: R.V. value
1: P.V. value
149 Preset memory DINT R/W 0
0: YES
1: NO
150 Preset point DINT R/W 0
0: Common to all banks
1: Store separately for each bank
151 Power-saving function (ECO) DINT R/W 0
0: OFF
1: HALF
2: ALL
152 Jam detection function DINT R/W 0
0: OFF
1: ON
2: USER
153 Jam detection position DINT R/W +000.5000 -199.9999 to +199.9999
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value