Instruction Manual
16
- PROFINET Communication Unit DL-PN1 User's Manual (IL) -
33 Sensor amplifier error state *1 DINT R
Bit0: Overcurrent error
Bit1: EEPROM error
Bit2: Sensor head error
Bit3: 0 (fixed)
Bit4: 0 (fixed)
Bit5: 0 (fixed)
Bit6: 0 (fixed)
Bit7: Spot light laser error
Bit8: Incompatible model
error
Bit9: 0 (fixed)
Bit10: 0 (fixed)
Bit11: Amplifier
communication error
Bit12: Number of units error
Bit13: Calculation error
Bit14: 0 (fixed)
Bit15: 0 (fixed)
34 to 35 Reserved for system
36
Judgment output/Alarm
output
*2
*19
DINT R
Bit0:
HIGH judgment output
0: OFF, 1: ON
Bit1: LOW judgment output
0: OFF, 1: ON
Bit2: GO judgment output
0: OFF, 1: ON
Bit3: Alarm output
0: OFF, 1: ON
37 Comparator value (P.V. value)
*3
*4
DINT R -99.999 to +99.999
38 Raw value (R.V. value) *4 DINT R -99.999 to +99.999
39
Peak hold value during hold
period
*4
*5
DINT R -99.999 to +99.999
40
Bottom hold value during hold
period
*4
*6
DINT R -99.999 to +99.999
41
Calculation value (CALC
value)
*3
*4
DINT R -99.999 to +99.999
42 Analog output value *7 DINT R
Analog voltage output:
-5.000 to +5.000
Analog current output:
+04.00 to +20.00
43 Bank status DINT R
0: Bank 0
1: Bank 1
2: Bank 2
3: Bank 3
44 Timing status DINT R
0: During Sampling
1: Not during sampling
45 to 49 Reserved for system
50 Laser emission stop state DINT R
0: Laser emitting
1: Laser stopped
51 Abnormal setting *8 DINT R
0: Normal setting
1: Abnormal setting
52 External input status *20 DINT R 0 to 15
53 EEPROM write result *9 DINT R 1
0: Writing
1: Normal termination
2: Abnormal termination
54
Zero shift/Zero shift reset
result
*10 DINT R 1
0: Executing
1: Normal termination
2: Abnormal termination
55 Reset request result *10 DINT R 1
0: Executing
1: Normal termination
2: Abnormal termination
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value