Instruction Manual

21
- PROFINET Communication Unit DL-PN1 User's Manual (IL) -
*2 Details of output status can be checked by noting the ON/OFF state of each bit.
*3 Use this parameter in combination with the judgment value property or with the
judgment value "invalid," "over," or "under."
If the judgment value is correct, the parameter range is
- from - 99.997 to +99.998 (IL-S025/IL-030/IL-S065/IL-065/IL-100).
- from - 999.97 to +999.98 (IL-300/IL-600).
- from - 9999.7 to +9999.8 (IL-2000).
For IL-S025/IL-030/IL-S065/IL-065/IL-100:
When the comparator value is over range, "+99.999" is stored.
When the comparator value is under range, "- 99.999" is stored.
When the comparator value is invalid, "- 99.998" is stored.
When an error occurs, "+100.000" is stored.
For IL-300/IL-600:
When the comparator value is over range, "+999.999" is stored.
When the comparator value is under range, "- 999.99" is stored.
When the comparator value is invalid, "- 999.98" is stored.
When an error occurs, "+1000.00" is stored.
For IL-2000:
When the comparator value is over range, "+9999.9" is stored.
When the comparator value is under range, "- 9999.9" is stored.
When the comparator value is invalid, "- 9999.8" is stored.
When an error occurs, "+10000" is stored.
*4 When using IL-300/IL-600, -999.99 to +999.99.
When using IL-2000, -9999.9 to +9999.9.
*5 - When in sample hold: Value "-99.998" is output.
- When not in sample hold: The peak value encountered during the sampling period
is output.
*6 - When in sample hold: Value "-99.998" is output.
- When not in sample hold: The bottom value encountered during the sampling
period is output.
*7 If the sensor amplifier is in error, the analog voltage output is +5.500 and the analog
current output is +03.00. For overcurrent errors and EEPROM errors, becomes the
voltage value (current value) based on the measurement value.
*8 If a prohibited combination of functions is written, it results in "abnormal setting (1)".
For details of each function, refer to the IL Series User's Manual.