User guide

14
- PROFINET Communication Unit DL-PN1 User’s Manual (SK-1000) -
Access Address (Slot 1 to 8)
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value
0 Reserved for system
1 Zero shift execution request DINT C
2
Zero shift reset execution
request
DINT C
3 Reset request DINT C
4 Reserved for system
5 Initial reset request DINT C
6
System parameter set
request
DINT C
7 to 31 Reserved for system
32 Group1 Entry Count DINT R 24
33 Sensor amplifier error state *1 DINT R
Bit0: Overcurrent error
Bit1: EEPROM error
Bit2: Sensor head error
Bit3: 0 (fixed)
Bit4: 0 (fixed)
Bit5: 0 (fixed)
Bit6: 0 (fixed)
Bit7: Head temperature/
humidity error
Bit8: 0 (fixed)
Bit9: 0 (fixed)
Bit10: 0 (fixed)
Bit11: Amplifier
communication error
Bit12: 0 (fixed)
Bit13: 0 (fixed)
Bit14: 0 (fixed)
Bit15: 0 (fixed)
34 to 35 Reserved for system
36
Judgment output/Alarm
output
*2
*16
DINT R
Bit0:
HI judgment output
0: OFF, 1: ON
Bit1: LO judgment output
0: OFF, 1: ON
Bit2: GO judgment output
0: OFF, 1: ON
Bit3: Alarm output
0: OFF, 1: ON
37 Comparator value (P.V. value) *3 DINT R -99.999 to +99.999
38 Raw value (R.V. value) DINT R -99.999 to +99.999
39
Peak hold value during hold
period
*4 DINT R -99.999 to +99.999
40
Bottom hold value during hold
period
*5 DINT R -99.999 to +99.999
41 to 42 Reserved for system
43 Bank status DINT R
0: Bank 0
1: Bank 1
2: Bank 2
3: Bank 3
44 Timing status DINT R
0: During Sampling
1: Not during sampling
45 Temperature *6 DINT R -999.9 to +999.9
46 Humidity *7 DINT R 0.0 to 100.0
47 to 50 Reserved for system
51 Abnormal setting *8 DINT R
0: Normal setting
1: Abnormal setting